Infusion Pump | BYS-820
SKU: BYS-820

Infusion Pump | BYS-820

The Infusion Pump is a sophisticated piece of Medical Equipment which provides for the exact and constant dispensation of fluids, drugs, nutrition and blood components in the medical facilities including hospitals, ICU units, operating theatres, emergency departments and medical establishments. The Infusion Pump includes such characteristics as programmable infusion rates, intelligent alarms, precise flow control and user-friendly digital display. The robust and compact design provides for uninterrupted working of the Infusion Pump in the critical care areas. A renowned Infusion Pump Manufacturer offers high-standard infusion systems in accordance with the international health care requirements.

Specifications

Feature
  • HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
  • Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
  • Compatible with any brands of infusion sets after correct calibration;
  • Preset solution volume to greatly reduce the workload of nurses;
  • Work mode: ml/h and drop/min can switch freely;
  • Three levels of occlusion: high, middle, and low;
  • Purge function;
  • KVO (keep-vein-open) automatically opens as the infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
  • Power Source: AC100—240V, 50/60Hz; Internal Battery;
  • Automatically record the settings of the last infusion;

    Performance Rate: 1 ml/h ~ 1,200 ml/h Flow Rate Accuracy: Within ±5% (after correct calibration) Mechanical Precision: Within ±2% Purge Rate: 100 ml/h ~ 1,000 ml/h (100 ml/h step) Infusion Volume: 1 ml ~ 9,999 ml Total Infusion Volume: 0.1 ml ~ 9,999.9 ml KVO Rate: 1 ml/h ~ 5 ml/h (1 ml/h step) Occlusion: High: 800 mmHg ±200 mmHg (106.7 kPa ±26.7 kPa) Medium: 500 mmHg ±100 mmHg (66.7 kPa ±13.3 kPa) Low: 300 mmHg ±100 mmHg (40.7 kPa ±13.3 kPa) Unique Audible and Visible Alarm: Human voice alarm for end of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out, etc. Power Source:
    • AC 100V ~ 240V, 50/60Hz
    • Internal rechargeable Li battery, capacity ≥1600 mAh
    • Internal battery backup

    Bubble Detector:
  • Ultrasonic wave detector
  • Detection sensitivity ≥25 μL
  • Fuse: F1AL / 250V, 2 pcs inside

Power Consumption: 18 VA Operating Condition:
  • Ambient temperature: +5°C ~ +40°C
  • Relative humidity: 20 ~ 90%
  • Atmospheric pressure: 86.0 kPa ~ 106.0 kPa
    Transport & Storage Condition:
  • Ambient temperature: −30°C ~ +55°C
  • Relative humidity: ≤95%
  • Equipment Classification: Class II, internal power supply, Type CF
  • IP Classification: IPX4

    Packing:
    • Dimensions: 40mm (L) x 157mm(W) x 220mm(H)
    • Weight - 1.8kg (net weight)

  • CONTACT US FOR PRICE

    Send Us a Message

    Enquire about this product

    Tell us your quantity, delivery location, or any questions. We'll respond with a quote or guidance.


    Chat on WhatsApp